UV accessory selection guide for solids

UV accessory selection guide for solids

Sample Analytical form and analytical condition Accessory
Solids Smooth surface samples (Metal, mirror, film, etc.) Transmittance Measurement Less than 3 mm thick Standard compartments+Film Holder
More than 3 mm thick Integrating Sphere Attachment (ISR-240A/2200/2600/3100) *
Large Integrating Sphere Attachment 150øIntegrating Sphere Attachment (LISR-3100) <UV-3600 only>
Large sample size Multipurpose Large-Sample Compartment (MPC-2200/2600/3100) * or SolidSpec-3700
Reflectance Measurement Relative Specular Reflectance Measurement Normal measurement Specular Reflectance Attachment (5゚ incident angle)
Large sample size SolidSpec-3700 + Large specular reflectance attachment (5゚ incident angle)
Absolute Specular Reflectance Measurement 5゚ incident angle measurement Absolute Specular Reflectance Attachment (ASR-3105) * <only MPC-2200/3100BIS-3100/3700>
12/30/45゚ incident angle measurement Absolute Specular Reflectance Attachment (ASR-3112/3130/3145) * <Requires MPC-2200/3100BIS-3100/3700Polarizer Assy>
Tilting incident measurement Tilting incident Absolute Specular Reflectance Attachment (Special Order) * +Requires Polarizer Assy and Multipurpose Large-Sample Compartment (MPC-2200/3100)
Relative Diffuse Reflectance Measurement Normal measurement Integrating Sphere Attachment (ISR-240A/2200/2600/3100) *
Large Integrating Sphere Attachment 150ØIntegrating Sphere Attachment (LISR-3100) <UV-3600 only>
Large sample size Multipurpose Large-Sample Compartment (MPC-2200//2600/3100) * or SolidSpec-3700
Rough surface sample (Paper, plastic, etc) Transmittance Measurement Normal measurement Integrating Sphere Attachment (ISR-240A/2200/2600/3100) *
Large Integrating Sphere Attachment 150ØIntegrating Sphere Attachment (LISR-3100) <UV-3600 only>
Large sample size Multipurpose Large-Sample Compartment (MPC-2200/2600/3100) * or SolidSpec-3700
Reflectance Measurement Relative Diffuse Reflectance Measurement Normal measurement Integrating Sphere Attachment (ISR-240A/2200/2600/3100) *
Large Integrating Sphere Attachment 150ØIntegrating Sphere Attachment (LISR-3100) <UV-3600 only>
Large sample size Multipurpose Large-Sample Compartment (MPC-2200/3100/2600) * or SolidSpec-3700
Absolute Diffuse Reflectance Measurement Please consult with your rep.
Large sample size Multipurpose Large-Sample Compartment (MPC-2200/2600/3100) * or SolidSpec-3700

* Accessory for UV-2450/2550/3600/SolidSpec-3700

 

For color measurement, the Color Measurement Software COL-UVPC is required separately.

For film thickness measurement, the Film Thickness Measurement Software FLM-UVPC is required separately.